The replenishing line (bleeder tube) in the multiple-tank dishwashing machine is tapped off the final rinse line after the shut-off size. The design should be such that under normal operation, the rate of replenish- ment can be-varied from zero to one and one half gallons per minute at rated water pressure. Improper installation of the bleeder tube is shown in Figure 7 (see Figure 6 for proper installation of the bleeder tube).
Figure 7 - Improper Installation Of Bleeder Tube On
Mechanical Dishwashing Machine
b. Instrument Readings
(1) Single and Multiple Type Dishwashing Machines
(a) Wash water thermometer (Single, Multiple) .- The
wash water thermometer should be maintained at a temperature of 150°F to 165°F.
(b) Rinse water thermometer (Multiple). - The rinse water thermometer should be maintained between 160°F and 180°F.
(c) Final rinse water thermometer (Single, Multiple).- The final rinse water should be maintained at a temperature of 180°F nor more than 195°F.