MIL-HDBK-740
g.
mix water in the
Safety precautions
(1) When operating the hot and cold water line valves to blender, always open the cold water line valve first and
place fingers in stream from blender.
(2) If pump motor smokes during operation, shut off motor and report condition to the installation facilities engineer.
(3) Make sure that all switches on the equipment are in
OFF position before plugging into outlet.
oil and water.
(4) Keep electric wiring and components free of grease,
(5) Never operate an electric switch with wet hands.
(6) Do not handle electric wiring at anytime. If any electrical work must be done, notify the installation facilities engineer.
(7) Pull the plug or turn switch to OFF position before attempting to clean or adjust the preflushing machine.
(8) When using the preflushing machine, follow all instructions posted on or near the machine, and never leave the machine while it is in operation.
(9) Keep floor free of boxes, trash, cleaning equipment, or any item that someone could trip over.
(10) Keep floor clean and dry. Cleanup any spilled food or liquid immediately.
(11) Get rid of dirt, grease, and trash promptly to reduce
fire hazzard.
2. Alternate Preflushing Equipment
a. Prerinse unit (Figure 16).- A complete prerinse unit
with mixing faucet to insure correct water temperature. The gooseneck reaches
12 inches over the sink at the top, with a swivel type base for increased
coverage.
25